NRG 200M Wind Vane

The 200M Wind Direction Vane features a remarkably accurate sensing element that produces no dead band, achieving lower uncertainty and 360° continuous measurement.

Product Configurations

FACTORY CALIBRATED

MEASNET Calibrated

MEASNET Calibrated, DWG



Details


NRG Systems 200M Wind Direction Vane brings significant upgrades to the proven design of our 200P Wind Direction Vane.

NEW IN THE 200M

  • No Dead Band: The 200M has 360° continuous measurement, whereas the 200P has an 8° max. dead band centered on 0°.
  • Reduced Sensor Uncertainty: The 200M's sensor uncertainty is ±1.6° across virtually its full range, whereas the 200P's sensor uncertainty outside the dead band region is ±4.3°.
  • Improved Vane Orientation Precision and Repeatability: The 200M's improved mounting system makes it easier to precisely determine sensor orientation once installed on a boom.
  • Firmer Mounting Connection: The 200M's new mounting system enables a firmer connection between the vane and mounting boom, making it less likely that vane orientation will drift over time.
  • Improved Protection Against Water and Dust Ingress: The 200M's bearing and electronics capsules are fully sealed against water and dust ingress, making it less likely that corrosion or dust will damage the sensor over time.
  • Transparent Records of Sensor Response and Quality: Factory calibration certificates with sensor-specific scale and offset values will be available at no extra cost. Download Calibration Report

MAINTAINED FROM THE 200P

  • Proven Aerodynamic Performance and Robustness: The 200M utilizes the same black, UV-stabilized injection molded plastic vane wing and sensor body that the 200P has been proving in the field for decades.
  • Easy Sensor Traceability: Individual unit serialization makes it easier to keep track of your wind vane's unique history and ties it to its sensor-specific slope and offset values determined during the manufacturing process or in a wind tunnel.
  • Easy Compatibility: The 200M’s simple voltage output is compatible with all industry-standard data loggers, including legacy NRG loggers, and is designed to work seamlessly with the NRG SymphoniePRO® Data Logger.
  • Low Power Draw: With a current draw of <500uAmps on SymphoniePRO wind vane channels, there is no need to increase the size of the standard power supplies you use today to accommodate the 200M.

PLEASE NOTE: A wind tunnel calibrated version of the sensor is also available. Wind tunnel calibration serves as an additional quality check and record that an individual wind vane is performing normally prior to installation on a met tower. A physical calibration report is included with each calibrated sensor. The calibration procedure is based on the following standards:

  • IEC 61400-12-1: Power performance measurements of electricity producing wind turbines
  • IEC 61400-12-2: Power performance of electricity producing wind turbines based on nacelle anemometry
  • ISO 16622: Meteorology - sonic anemometers/thermometers
  • ASTM 5366-96: Standard Test Method of Measuring the Dynamic Performance of Wind Vanes

BENEFITS


  • Same vane and body design as 200P ensures seamless transition to 200M
  • Like the 200P, the 200M is compatible with all Symphonie Data Loggers
  • Field-tested materials for long-lasting durability
  • New magnetic encoder-based signal generator means accurate data are available in all wind directions
  • Improved mounting precision lowers measurement uncertainty
  • Factory calibration certificates with sensor-specific scale and offset values reduce uncertainty caused by sensor-to-sensor variability

Specifications


  Factory Calibrated MEASNET Calibrated, DWG MEASNET Calibrated
Description
Sensor type Continuous rotation wind direction vane Continuous rotation wind direction vane n/a
Applications
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
n/a
Sensor range 360° mechanical, continuous rotation
Maximum sustained wind speed > 90 m/s
360° mechanical, continuous rotation
Maximum sustained wind speed > 90 m/s
n/a
Instrument compatibility All Symphonie Data Loggers All Symphonie Data Loggers n/a
Measurement range 0 - 360° 1 to 75 m/s 0 - 360° 1 to 75 m/s n/a
Output signal
Signal type Analog DC voltage Analog DC voltage n/a
Linearity 0.1° 0.1° n/a
Transfer function SymphoniePRO:
  • Default slope = 147.91°/V
  • Default offset = -1.460°

    SymphoniePLUS3:
  • Default slope = 0.368°/V
  • Default offset = -5.3°
SymphoniePRO:
  • Default slope = 147.91°/V
  • Default offset = -1.460°

    SymphoniePLUS3:
  • Default slope = 0.368°/V
  • Default offset = -5.3°
n/a
Dead band None None n/a
Calibration Each sensor is individually factory calibrated. Factory calibration certificates provided via electronic download. Each sensor is individually factory calibrated and calibrated at DWG wind tunnel per IEC 61400-12-1 Ed. 2 Part 12-1. Factory and DWG wind tunnel calibration certificates available via electronic download. n/a
Output signal range 0.007Vdc to 2.5Vdc 0.007Vdc to 2.5Vdc n/a
Resolution 0.088° 0.088° n/a
Uncertainty Expanded uncertainty (k=2) 95% confidence [Sensor only]:
  • +/-1.6° (>0.9° to <359.1°)
  • +/-2.5° (359.1° to 0.9°)
Expanded uncertainty (k=2) 95% confidence [Sensor only]:
  • +/-1.6° (>0.9° to <359.1°)
  • +/-2.5° (359.1° to 0.9°)
n/a
Response characteristics
Threshold 0.97 m/s (2.16 mph) at 90° per ASTM D5366-96 0.97 m/s (2.16 mph) at 90° per ASTM D5366-96 n/a
Delay distance 1.18 m (@5 m/s), 1.20 (@10 m/s) per ASTM D5366-96 1.18 m (@5 m/s), 1.20 (@10 m/s) per ASTM D5366-96 n/a
Power requirements
Supply voltage 4.5 Vdc to 15 Vdc 4.5 Vdc to 15 Vdc n/a
Supply current 1.5mA 1.5mA n/a
Installation
Mounting Onto a 13 mm (0.5") diameter mast with cotter pin and #2 phillips set screw. Onto a 13 mm (0.5") diameter mast with cotter pin and #2 phillips set screw. n/a
Tools required #2-Phillips driver, 0.25" nut driver, petroleum jelly, electrical tape #2-Phillips driver, 0.25" nut driver, petroleum jelly, electrical tape n/a
Environmental
Operating temperature range -40°C to 60°C (-40°F to 140°F) -40°C to 60°C (-40°F to 140°F) n/a
Operating humidity range 0 to 100% RH 0 to 100% RH n/a
Physical
Connections 4-40 nickel plated brass hex nut/post terminals 4-40 nickel plated brass hex nut/post terminals n/a
Weight 0.108 kg (0.238 pounds) 0.108 kg (0.238 pounds) n/a
Dimensions
  • 21 cm (8.3 inches) length x 12 cm (4.3 inches) height
  • 27 cm (10.5 inches) swept diameter
  • 21 cm (8.3 inches) length x 12 cm (4.3 inches) height
  • 27 cm (10.5 inches) swept diameter
n/a
Materials
Wing Black UV stabilized injection-molded plastic Black UV stabilized injection-molded plastic n/a
Body Black UV stabilized static-dissipating plastic Black UV stabilized static-dissipating plastic n/a
Shaft Stainless steel Stainless steel n/a
Bearing Stainless steel Stainless steel n/a
Magnet Neodymium Neodymium n/a
Boot Protective PVC sensor terminal boot included Protective PVC sensor terminal boot included n/a
Terminals Nickel plated brass Nickel plated brass n/a

PRODUCT SUPPORT